Leave Your Message

Bioland™ Closed Transfer System for Contamination Control - Reliable China Suppliers and Factory Solutions

,

Advanced Contamination Control Solution from China
Bioland™ offers a Closed Transfer System (CTS) designed specifically for cell culture processes, providing an integrated containment solution that significantly reduces contamination risks during essential operations. Our system ensures a sterile environment while facilitating the necessary gas exchange, making it a preferred choice among suppliers in the biotechnology industry.

,

Technical Specifications

,

Equipped with an integrated 0.22 µm hydrophobic membrane filter (sterilizing grade)

,

Manufactured in a state-of-the-art ISO 7 (Class 10,000) cleanroom environment

,

Features one-piece injection molded two-port caps with a secure connection design for enhanced reliability

,

TPE tubing compatible with heat sealing and welding processes for superior durability

,

Available with standard MPC and Luer lock connectors for versatile connectivity

,

Constructed from USP Class VI certified materials ensuring safety and compliance

,

Achieves a Sterility Assurance Level (SAL) of 10⁻⁶, ensuring maximum sterility

,

Endotoxin-free and entirely devoid of animal-derived components (ADCF)

,

Choose Bioland™ as your trusted supplier and factory in China for cutting-edge contamination control solutions.

,

    More Details
    Design Features
    • Leak-proof connections prevent accidental disconnections
    • Heat-sealable tubing for closed system integrity
    • Gas-permeable, hydrophobic membrane prevents microbial ingress
    • Ready-to-use sterile configuration
    Customization
    Custom-engineered solutions available to meet specific process requirements and application needs.
    Product Specifications
    Order No. Description Package
    F125-2-3 125ml ; with 0.22um air filter ; TPE welded heat sealing tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; heat sealing of the tube. 1/Pk 6/Box
    F125-F2-3L 125ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with Luer male connector 1/Pk 6/Box
    F125-F2-3M 125ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with MPC female connector 1/Pk 6/Box
    F125-2-3S 125ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with S series sterile connector 1/Pk 6/Box
    F125-2-6 125ml ; with 0.22um air filter ; TPE welded heat sealing tube ; inner diameter of 1/4 inch, outer diameter of 3/8 inch ; heat sealing of the tube. 1/Pk 6/Box
    F125-F2-6L 125ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with Luer male connector 1/Pk 6/Box
    F125-F2-6M 125ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with MPC female connector 1/Pk 6/Box
    F125-2-6S 125ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with S series sterile connector 1/Pk 6/Box
    F250-2-3 250ml ; with 0.22um air filter ; TPE welded heat sealing tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; heat sealing of the tube mouth. 1/Pk 6/Box
    F250-F2-3L 250ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with Luer male connector 1/Pk 6/Box
    F250-F2-3M 250ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with MPC female connector 1/Pk 6/Box
    F250-2-3S 250ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with S series sterile connector 1/Pk 6/Box
    F250-2-6 250ml ; with 0.22um air filter ; TPE welded heat sealing tube ; inner diameter of 1/4 inch, outer diameter of 3/8 inch ; heat sealing of the tube. 1/Pk 6/Box
    F250-F2-6L 250ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with Luer male connector 1/Pk 6/Box
    F250-F2-6M 250ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with MPC female connector 1/Pk 6/Box
    F250-2-6S 250ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with S series sterile connector 1/Pk 6/Box
    F500-2-3 500ml ; with 0.22um air filter ; TPE welded heat sealing tube ; inner diameter of the tube is 1/8 inch, outer diameter of the tube is 1/4 inch ; heat sealing of the tube mouth. 1/Pk 4/Box
    F500-F2-3L 500ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with Luer male connector 1/Pk 4/Box
    F500-F2-3M 500ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with MPC female connector 1/Pk 4/Box
    F500-2-3S 500ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with S series sterile connector 1/Pk 4/Box
    F500-2-6 500ml ; with 0.22um air filter ; TPE welded heat sealing tube ; inner diameter of 1/4 inch, outer diameter of 3/8 inch ; heat sealing of the tube. 1/Pk 4/Box
    F500-F2-6L 500ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with Luer male connector 1/Pk 4/Box
    F500-F2-6M 500ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with MPC female connector 1/Pk 4/Box
    F500-2-6S 500ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with S series sterile connector 1/Pk 4/Box
    F1000-2-3 1000ml ; with 0.22um air filter ; TPE welded heat sealing tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; heat sealing tube. 1/Pk 3/Box
    F1000-F2-3L 1000ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with Luer male connector 1/Pk 3/Box
    F1000-F2-3M 1000ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with MPC female connector 1/Pk 3/Box
    F1000-2-3S 1000ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/8 inch, outer diameter 1/4 inch ; tube end with S series sterile connector 1/Pk 3/Box
    F1000-2-6 1000ml ; with 0.22um air filter ; TPE welded heat sealing tube ; inner diameter of 1/4 inch, outer diameter of 3/8 inch ; heat sealing of the tube. 1/Pk 3/Box
    F1000-F2-6L 1000ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with Luer male connector 1/Pk 3/Box
    F1000-F2-6M 1000ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with MPC female connector 1/Pk 3/Box
    F1000-2-6S 1000ml ; with 0.22 μm air filter ; TPE welded heat-sealed tube ; inner diameter 1/4 inch, outer diameter 3/8 inch ; tube end with S series sterile connector 1/Pk 3/Box
    Product Show
    Frequently Asked Questions
    Q What volume sizes are available for the Bioland™ Erlenmeyer Flask Closed Transfer System?
    The system is available in four volume sizes: 125ml, 250ml, 500ml, and 1000ml, accommodating a wide range of bioprocessing and cell culture applications.
    Q What type of tubing is used, and what sizes are available?
    The system uses TPE (thermoplastic elastomer) welded heat-sealed tubing. Two tube sizes are available: inner diameter 1/8 inch with outer diameter 1/4 inch, and inner diameter 1/4 inch with outer diameter 3/8 inch.
    Q What connector options are available at the tube end?
    The tube end can be configured with a heat-sealed closure (no connector), a Luer male connector, an MPC female connector, or an S series sterile connector — providing flexibility for different process integration needs.
    Q How does the system maintain sterility during fluid transfer?
    The system maintains sterility through multiple design features: leak-proof connections that prevent accidental disconnections, heat-sealable tubing that ensures closed system integrity, and a gas-permeable, hydrophobic membrane air filter (0.22 μm) that prevents microbial ingress while allowing gas exchange.
    Q Is the Erlenmeyer Flask Closed Transfer System ready to use out of the box?
    Yes. The system comes in a ready-to-use sterile configuration, eliminating the need for pre-sterilization steps and reducing preparation time in the lab or manufacturing environment.
    Q Can the system be customized for specific process requirements?
    Yes. Custom-engineered solutions are available to meet specific process requirements and application needs. Please contact the manufacturer directly to discuss your particular specifications and requirements.