China Bioland™ HM Series Infrared Inoculation Ring Sterilizer - Reliable Suppliers & Factory for Microbial Experiments
Product Specifications
| Order NO. | HM150-14 | HM100-35 |
| Input power | AC220V, 50HZ | AC220V, 50HZ |
| Maximum temperature in the center area of the heating body | 825 ℃ + 50 ℃ | 825 ℃ + 50 ℃ |
| Maximum outside diameter of sterilized items | 14mm | 35mm |
| Heating zone length | 150mm | 100mm |
| Heat to maximum temperature time | 20min | 20min |
| Ambient temperature for use | 5 ℃ and 40 ℃ | 5 ℃ and 40 ℃ |
| Overall dimensions (mm) | 90 x 160 x 195 | 90 x 140 x 225 |
| Weight | 1.3 kg | 1.5 kg |
?
Frequently Asked Questions
Q
What is the difference between the HM150-14 and the HM100-35 models?
A
The main differences lie in the heating zone length and the maximum outside diameter of sterilized items. The HM150-14 has a 150mm heating zone and accommodates items up to 14mm in diameter, while the HM100-35 has a 100mm heating zone and supports items up to 35mm in diameter. Both models share the same input power, maximum temperature, heat-up time, and ambient temperature range.
Q
What is the maximum sterilization temperature these units can reach?
A
Both the HM150-14 and HM100-35 models can reach a maximum temperature of 825 ℃ ± 50 ℃ in the center area of the heating body, making them highly effective for high-temperature sterilization applications.
Q
How long does it take to heat up to the maximum temperature?
A
Both models require approximately 20 minutes to heat up from a cold start to the maximum operating temperature. This consistent warm-up time applies to both the HM150-14 and the HM100-35.
Q
What type of power supply is required for these sterilizers?
A
Both units operate on a standard AC 220V, 50Hz power supply. Please ensure your facility provides this electrical specification before installation and use.
Q
What ambient temperature range is suitable for operating these sterilizers?
A
Both the HM150-14 and HM100-35 are designed to be used in environments with an ambient temperature between 5 ℃ and 40 ℃. Operating outside this temperature range may affect performance and is not recommended.
Q
Which model should I choose if I need to sterilize larger diameter instruments?
A
If you need to sterilize instruments or tools with a larger outside diameter (up to 35mm), the HM100-35 model is the appropriate choice. For items with a smaller diameter (up to 14mm) but requiring a longer heating zone (150mm), the HM150-14 would be more suitable.